Skip to main page content
U.S. flag

An official website of the United States government

Dot gov

The .gov means it’s official.
Federal government websites often end in .gov or .mil. Before sharing sensitive information, make sure you’re on a federal government site.

Https

The site is secure.
The https:// ensures that you are connecting to the official website and that any information you provide is encrypted and transmitted securely.

Access keys NCBI Homepage MyNCBI Homepage Main Content Main Navigation

Search Page

Filters

My NCBI Filters

Results by year

Table representation of search results timeline featuring number of search results per year.

Year Number of Results
1934 1
1940 2
1946 1
1947 2
1948 3
1949 3
1950 5
1951 6
1952 3
1953 7
1954 6
1955 5
1956 5
1957 9
1958 11
1959 13
1960 4
1961 11
1962 13
1963 15
1964 25
1965 24
1966 30
1967 33
1968 48
1969 41
1970 41
1971 44
1972 49
1973 64
1974 52
1975 211
1976 204
1977 190
1978 160
1979 189
1980 212
1981 268
1982 288
1983 356
1984 362
1985 350
1986 339
1987 351
1988 338
1989 393
1990 351
1991 372
1992 336
1993 307
1994 347
1995 356
1996 352
1997 390
1998 301
1999 287
2000 299
2001 278
2002 305
2003 258
2004 269
2005 283
2006 273
2007 254
2008 234
2009 206
2010 241
2011 250
2012 276
2013 224
2014 268
2015 254
2016 240
2017 234
2018 255
2019 243
2020 286
2021 262
2022 246
2023 206
2024 91

Text availability

Article attribute

Article type

Publication date

Search Results

13,788 results

Results by year

Filters applied: . Clear all
Page 1
Potential Induced Radioactivity in Materials Processed with X-ray Energy Above 5 MeV.
Michel H, Kroc T, McEvoy BJ, Patil D, Reppert P, Smith MA. Michel H, et al. Biomed Instrum Technol. 2021 Mar 1;55(s3):17-26. doi: 10.2345/0899-8205-55.s3.17. Biomed Instrum Technol. 2021. PMID: 34153999 Free PMC article.
Section 5.1.2 of ANSI/AAMI/ISO 11137-1 states that "the potential for induced radioactivity in product shall be assessed." This article describes how compliance with this requirement may be achieved using qualified test methods. ...
Section 5.1.2 of ANSI/AAMI/ISO 11137-1 states that "the potential for induced radioactivity in product shall be assessed." Thi …
Technical Note: Induced radioactivity in stereotactic body radiation therapy with a flattening-filter-free 10 MV beam model.
Wang H, Chen K, Shi Y, Huang X, Sun W, Hou K, Jin Y, Jiang X, Yang D, Dong L. Wang H, et al. Med Phys. 2021 Apr;48(4):2010-2017. doi: 10.1002/mp.14747. Epub 2021 Mar 1. Med Phys. 2021. PMID: 33524168
PURPOSE: The induced radioactivity in stereotactic body radiation therapy with a flattening-filter-free 10 MV beam model (10 FFF SBRT) was investigated for the risk to therapists. ...(d) The estimated annual dose to therapists was up to 0.20 mSv/y. CONCLUSIONS: The …
PURPOSE: The induced radioactivity in stereotactic body radiation therapy with a flattening-filter-free 10 MV beam model (10 F …
Studies of radioactivity produced by the Hiroshima atomic bomb: 1. Neutron-induced radioactivity measurements for dose evaluation.
Hoshi M, Hasai H, Yokoro K. Hoshi M, et al. J Radiat Res. 1991 Mar;32 Suppl:20-31. doi: 10.1269/jrr.32.supplement_20. J Radiat Res. 1991. PMID: 1762107 Free article. Review.
This review summarizes measurements made of 152Eu and 60Co radioactivity induced by neutron radiation from the Hiroshima atomic bomb (A-bomb) with the goal of estimating the neutron dose released by the bomb. Prior to these measurements, A-bomb-irradiated specimens …
This review summarizes measurements made of 152Eu and 60Co radioactivity induced by neutron radiation from the Hiroshima atomi …
Induced Radioactivity in Lead Shielding at the National Synchrotron Light Source.
Ghosh VJ, Schaefer C, Kahnhauser H. Ghosh VJ, et al. Health Phys. 2017 Jun;112(6):533-543. doi: 10.1097/HP.0000000000000651. Health Phys. 2017. PMID: 28441285
The FLUKA code, a fully integrated Monte Carlo simulation package for the interaction and transport of particles and nuclei in matter, was used to estimate induced radioactivity in this shielding and stainless steel beam pipe from known beam losses. ...FLUKA activit …
The FLUKA code, a fully integrated Monte Carlo simulation package for the interaction and transport of particles and nuclei in matter, was u …
Study on induced radioactivity and individual dose evaluation in Gantry room for Varian ProBeam Proton Therapy System.
Luo C, Li W, Li Y, Han X, Yang B, Su Y, Khasanov S, Liu X, Mao W, Yan W. Luo C, et al. Appl Radiat Isot. 2024 Jun;208:111297. doi: 10.1016/j.apradiso.2024.111297. Epub 2024 Mar 19. Appl Radiat Isot. 2024. PMID: 38513476
This study focuses on systematically investigating the induced radioactivity in the gantry room during pencil beam scanning, utilizing both experimental measurements and Monte Carlo simulations. Results indicate that patients are the primary source of induced
This study focuses on systematically investigating the induced radioactivity in the gantry room during pencil beam scanning, u …
Induced radioactivity in and around high-energy particle accelerators.
Vincke H, Theis C, Roesler S. Vincke H, et al. Radiat Prot Dosimetry. 2011 Jul;146(4):434-9. doi: 10.1093/rpd/ncr245. Epub 2011 Jun 22. Radiat Prot Dosimetry. 2011. PMID: 21697180
Particle accelerators and their surroundings are locations of residual radioactivity production that is induced by the interaction of high-energy particles with matter. ...Techniques used to obtain, on the one hand, estimates of radioactivity in Becquerel and …
Particle accelerators and their surroundings are locations of residual radioactivity production that is induced by the interac …
Evaluation of radioactivity in the bodies of mice induced by neutron exposure from an epi-thermal neutron source of an accelerator-based boron neutron capture therapy system.
Nakamura S, Imamichi S, Masumoto K, Ito M, Wakita A, Okamoto H, Nishioka S, Iijima K, Kobayashi K, Abe Y, Igaki H, Kurita K, Nishio T, Masutani M, Itami J. Nakamura S, et al. Proc Jpn Acad Ser B Phys Biol Sci. 2017;93(10):821-831. doi: 10.2183/pjab.93.051. Proc Jpn Acad Ser B Phys Biol Sci. 2017. PMID: 29225308 Free PMC article.
This study aimed to evaluate the residual radioactivity in mice induced by neutron irradiation with an accelerator-based boron neutron capture therapy (BNCT) system using a solid Li target. The radionuclides and their activities were evaluated using a high-purity ge …
This study aimed to evaluate the residual radioactivity in mice induced by neutron irradiation with an accelerator-based boron …
Comparing the effects of various (p,xn) radionuclide production routes on induced radioactivity in the concrete walls of a cyclotron vault.
Fang PW, Hsieh YI, Sheu RJ. Fang PW, et al. Radiat Prot Dosimetry. 2023 Oct 11;199(15-16):1941-1946. doi: 10.1093/rpd/ncac240. Radiat Prot Dosimetry. 2023. PMID: 37819332
The secondary neutrons accompanying these production routes could induce varying degrees of material activation in the cyclotron facility. Accordingly, this study compared the effects of various (p,xn) production routes on the neutron-induced long-lived radioacti
The secondary neutrons accompanying these production routes could induce varying degrees of material activation in the cyclotron faci …
Discovery of neutron activation analysis.
Landsberger S. Landsberger S. Appl Radiat Isot. 2022 Nov;189:110422. doi: 10.1016/j.apradiso.2022.110422. Epub 2022 Aug 18. Appl Radiat Isot. 2022. PMID: 36049442
However, there were many other researchers in Europe that firstly unknowingly and knowingly discovered the neutron, and others who experimented in neutron induced radioactivity. A historical timeline of the several parallel experiments in a very short period is give …
However, there were many other researchers in Europe that firstly unknowingly and knowingly discovered the neutron, and others who experimen …
13,788 results
You have reached the last available page of results. Please see the User Guide for more information.